1 - 10 of 34 results

HAGER SPM215D - transient voltage limiter 15 KA monofasico

Product no.: 112556

In stock, available in 24 horas

PVP. 189.96 €
51.30
You save 138.66 €

Price includes VAT

Price reductions

Transient overvoltage limit monobloc type 2, 1P + N, 15 kA, 275V for general protection of non-sensitive material in single-phase installations.

This limiter complies with all the regulations required for the protection of transient overvoltages in single-phase installations.

A surge protector with average discharge capacity, parallel connection with receptors protect and secure protection in common mode and differential mode.

Technical characteristics

  • Built according to UNE EN 61643-11 and EN 50539-11
  • Mounting Type: DIN Rail
  • Number of modules: 2
  • Number of semi-modules of 17,5mm only for instrument and kit: 4
  • Number of poles: 2 P
  • IP protection rating: IP20
  • Signal current remote: No
  • Rated discharge current (In): 5 kA
  • You have. Max. In rég. Perm. Common mode: 275 V
  • Rated Frequency: 50/60 Hz
  • Tightening torque: 3,6 Nm
  • Connection section in flexible cable: 25 mm²
  • Connection in rigid cable: 35 mm²
  • Connection section in flexible earth cable: 25 mm²
  • Connection section in rigid ground cable: 35 mm²
  • Height: 2000 m
  • Width of installed product: 36 mm
  • Corr. Desc. Max (Imax) or Imp (Iimp): 15 kA
  • Degree of pollution / IEC60664 / IEC60947-2: 2
  • Protection level Up to IEC61643-1: 1 kV
  • Light pilot: End of life indicator
  • Storage temperature: -40 to 80 ° C
  • Operating temperature: -40 to 55 ° C

 

Reference. HAGER SPM215D

 

The discount applied to the PVP is -73%

Additional product information

DATA SHEET: Download
SECURE PAYMENT: PayPal, Card, Transfer or Cash on Delivery.
FREE SHIPPING: For orders over €99, the rest is only €4.90 (mainland Spain).
EXPRESS DELIVERY: With MRW in 24/48 working hours depending on the delivery point (penin. Spain).

We also recommend

*

Prices include VAT


Customers who bought this product also bought

*

Prices include VAT


Browse these categories as well: OVERVOLTAGE LIMITERS / PROTECTORS, HAGER SURGE PROTECTION

HAGER SPM415D - KA 15 restrictor three-phase transient overvoltage

Product no.: 112563

In stock, available in 24 horas

PVP. 313.69 €
116.00
You save 197.69 €

Price includes VAT

Price reductions

Monobloc transient overvoltage limit switch type 2, 3P + N, 15 kA, 440 / 275V for general protection of non-sensitive material in three-phase installations.

This limiter complies with all the regulations required for the protection of transient overvoltages in three-phase installations.

An overvoltage protector with medium discharge capacity, connection in parallel with the receivers to be protected and with protection secured in common mode and in differential mode.

Technical characteristics

  • Built according to UNE EN 61643-11 and EN 50539-11
  • Mounting Type: DIN Rail
  • Number of modules: 4
  • Number of half modules of 17,5mm only for device and kit: 2
  • IP protection rating: IP20
  • Signal current remote: No
  • Rated discharge current (In): 5 kA
  • You have. Max. In rég. Perm. In common mode: 440/275 V
  • Rated Frequency: 50/60 Hz
  • Tightening torque: 3,6 Nm
  • Connection section in flexible cable: 1,5 / 16 mm²
  • Connection in rigid cable: 1,5 / 25 mm²
  • Height: 2000 m
  • Installed product height: 86.5 mm
  • Width of the installed product: 72 mm
  • Depth of installed appliance: 60 mm
  • Corr. Desc. Max (Imax) or Imp (Iimp): 15 kA
  • Degree of pollution / IEC60664 / IEC60947-2: 2
  • Protection level Up to IEC61643-1: 1 kV
  • Light pilot: End of life indicator
  • Storage temperature: -40 to 80 ° C
  • Operating temperature: -40 to 60 ° C

 

Reference. HAGER SPM415D

 

The discount applied to the PVP is -63%

Additional product information

DATA SHEET: Download
SECURE PAYMENT: PayPal, Card, Transfer or Cash on Delivery.
FREE SHIPPING: For orders over €99, the rest is only €4.90 (mainland Spain).
EXPRESS DELIVERY: With MRW in 24/48 working hours depending on the delivery point (penin. Spain).

We also recommend

*

Prices include VAT


Customers who bought this product also bought

*

Prices include VAT


Browse these categories as well: OVERVOLTAGE LIMITERS / PROTECTORS, HAGER SURGE PROTECTION

HAGER MZ225N - Transient Surge permanante + 2P 25A

Product no.: 112510

In stock, available in 24 horas

PVP. 324.36 €
107.00
You save 217.36 €

Price includes VAT

Price reductions

Set of combined protection against transient and permanent surges associated to 2P automatic general switch, cutting power 6000A according to UNE EN 60898-1 Curve C, rated current 25A.

Set of combined protection against transient and permanent surges associated to 2P automatic general switch, cutting power 6000A according to UNE EN 60898-1 Curve C, rated current 25A.

With the HAGER MZ225N, the installation is protected against transient voltage peaks and against permanent voltage surges. Typically, the former are associated with the lightning phenomenon and the latter with the bad connection / breakdown of the three-phase installation neutral.

Technical specifications of the HAGER MZ225N

  • According to the standards: UNE EN 50550, UNE EN 61643-11, UNE EN 60898-1
  • Number of half modules of 17,5mm only for instrument and kit: 10
  • Number of poles: 2 P
  • Number of modules: 5
  • Rated rated current: 25 A
  • Rated current at 20º C: 27 A
  • Rated current at 30 ° C: 25 A
  • Rated current at 35 ° C: 24 A
  • Rated current at 40 ° C: 23 A
  • Rated insulation voltage: 500 V
  • Rated current at 45 ° C: 22 A
  • Rated current at 50 ° C: 21 A
  • Rated current at 55 ° C: 20 A
  • Rated current at 60 ° C: 19 A
  • Rated current at 70 ° C: 17 A
  • Curve: C
  • Power cut-off according to NF EN60898: 6 kA
  • Ten. Asig. Of resistance to shocks: 4000 V
  • Rated Frequency: 50/60 Hz
  • Connection Type: Cage with screw
  • Connection section in flexible cable: 6 mm²
  • Tightening torque: 1, 2 Nm
  • Connection in rigid cable: 10 mm²
  • Connection Sec. Born Sup And inf. Rigid cable: 1/25 mm²
  • Connection Sec. Sup. Flexible cable: 1/16 mm²
  • Height: 2000 m
  • Installed product height: 86.5 mm
  • Width of installed product: 87.5 mm
  • Depth of installed appliance: 70 mm
  • Coef. Correcc. Corr. Nom. 2 apar.yuxtap .: 1
  • Coef. Correcc. Corr. Nom. 3 apar.yuxtap .: 0.95
  • Coef. Correcc. Corr. Nom. 4 and 5 ap.yux ..: 0.9
  • Coef. Correcc. Corr. Nom. 6 pair.:x .: 0.85
  • Coef. Of correction. Magnetic trip 200Hz: 1.2
  • Coef. Of correction. 400Hz magnetic trip: 1.5
  • Coef. Of correction. Magnetic trip 60Hz: 1
  • Coef.correc. 100Hz magnetic trip: 1,1
  • Degree of pollution / IEC60664 / IEC60947-2: 3
  • Electrical endurance in number of cycles: 10000
  • Mechanical endurance in number of maneuvers: 10000
  • Threshold value min / max relay magn. In c.a .: 5/10 In
  • Threshold value min / max thermal relay in c.c: 1,13 / 1,45 In
  • Min. Threshold value Thermal relay in a .: 1,13 / 1,45 In
  • Threshold value min / max function. Thermal dc: 5/15 In
  • Power cut 1 Pol. IT400V (NF EN60947-2): 3 kA
  • Power cut last AC. 230V (NF 60947-2): 1 kA
  • Rated cutting power: 6 kA
  • Rated cutting power: 6 kA
  • Total power dissipated in IN: 7.1 W
  • Storage temperature: -25 to 80 ° C
  • Operating temperature: -25 to 60 ° C

 

Reference. HAGER MZ225N

 

The discount applied to the PVP is -67%

Additional product information

DATA SHEET: Download
SECURE PAYMENT: PayPal, Card, Transfer or Cash on Delivery.
FREE SHIPPING: For orders over €99, the rest is only €4.90 (mainland Spain).
EXPRESS DELIVERY: With MRW in 24/48 working hours depending on the delivery point (penin. Spain).

We also recommend

*

Prices include VAT


Customers who bought this product also bought

*

Prices include VAT


Browse these categories as well: OVERVOLTAGE LIMITERS / PROTECTORS, TOP SALES ELECTRICAL EQUIPMENT, HAGER SURGE PROTECTION

HAGER MZ232N - Transient Surge permanante + 2P 32A

Product no.: 112511

In stock, available in 24 horas

PVP. 335.47 €
109.00
You save 226.47 €

Price includes VAT

Price reductions

Set of combined protection against Transient and Permanent surges associated to 2P automatic general switch, cutting power 6000A according to UNE EN 60898-1 Curve C, rated current 32A.

With the HAGER MZ232N, the installation is protected against transient voltage peaks and against permanent voltage surges. Typically, the former are associated with the lightning phenomenon and the latter with the bad connection / breakdown of the three-phase installation neutral.

Technical characteristics of the HAGER MZ232N

  • According to the standards: UNE EN 50550, UNE EN 61643-11, UNE EN 60898-1
  • Number of half modules of 17,5mm only for instrument and kit: 10
  • Number of poles: 2 P
  • Number of modules: 5
  • Rated rated current: 32 A
  • Rated current at 20º C: 34.6 A
  • Rated current at 30 ° C: 32 A
  • Rated current at 35 ° C: 30.7 A
  • Rated current at 40 ° C: 29.4 A
  • Rated insulation voltage: 500 V
  • Rated current at 45 ° C: 28.2 A
  • Rated current at 50 ° C: 26.9 A
  • Rated current at 55 ° C: 25.6 A
  • Rated current at 60 ° C: 24.3 A
  • Rated current at 70 ° C: 21.8 A
  • Curve: C
  • Power cut-off according to NF EN60898: 6 kA
  • Ten. Asig. Of resistance to shocks: 4000 V
  • Rated Frequency: 50/60 Hz
  • Connection Type: Cage with screw
  • Connection section in flexible cable: 6 mm²
  • Tightening torque: 1, 2 Nm
  • Connection in rigid cable: 10 mm²
  • Connection Sec. Born Sup And inf. Rigid cable: 1/25 mm²
  • Connection Sec. Sup. Flexible cable: 1/16 mm²
  • Height: 2000 m
  • Installed product height: 86.5 mm
  • Width of installed product: 87.5 mm
  • Depth of installed appliance: 70 mm
  • Coef. Correcc. Corr. Nom. 2 apar.yuxtap .: 1
  • Coef. Correcc. Corr. Nom. 3 apar.yuxtap .: 0.95
  • Coef. Correcc. Corr. Nom. 4 and 5 ap.yux ..: 0.9
  • Coef. Correcc. Corr. Nom. 6 pair.:x .: 0.85
  • Coef. Of correction. Magnetic trip 200Hz: 1.2
  • Coef. Of correction. 400Hz magnetic trip: 1.5
  • Coef. Of correction. Magnetic trip 60Hz: 1
  • Coef.correc. 100Hz magnetic trip: 1,1
  • Degree of pollution / IEC60664 / IEC60947-2: 3
  • Electrical endurance in number of cycles: 10000
  • Mechanical endurance in number of maneuvers: 10000
  • Threshold value min / max relay magn. In c.a .: 5/10 In
  • Threshold value min / max thermal relay in c.c: 1,13 / 1,45 In
  • Min. Threshold value Thermal relay in a .: 1,13 / 1,45 In
  • Threshold value min / max function. Thermal dc: 5/15 In
  • Power cut 1 Pol. IT400V (NF EN60947-2): 3 kA
  • Power cut last AC. 230V (NF 60947-2): 1 kA
  • Rated cutting power: 6 kA
  • Rated cutting power: 6 kA
  • Total power dissipated in IN: 8.3 W
  • Storage temperature: -25 to 80 ° C
  • Operating temperature: -25 to 60 ° C

 

​Reference. HAGER MZ232N

 

The discount applied to the PVP is -67%

Additional product information

DATA SHEET: Download
SECURE PAYMENT: PayPal, Card, Transfer or Cash on Delivery.
FREE SHIPPING: For orders over €99, the rest is only €4.90 (mainland Spain).
EXPRESS DELIVERY: With MRW in 24/48 working hours depending on the delivery point (penin. Spain).

We also recommend

*

Prices include VAT


Customers who bought this product also bought

*

Prices include VAT


Browse these categories as well: OVERVOLTAGE LIMITERS / PROTECTORS, HAGER SURGE PROTECTION

HAGER MZ240N - Transient Surge permanante + 2P 40A

Product no.: 112512

In stock, available in 24 horas

PVP. 339.16 €
109.50
You save 229.66 €

Price includes VAT

Price reductions

Combined protection set against Transient and Permanent surges associated to 2P automatic general switch, cutting power 6000A according to UNE EN 60898-1 Curve C, rated current 40A.

With the HAGER MZ240N, the installation is protected against transient voltage peaks and against permanent voltage surges. Typically, the former are associated with the lightning phenomenon and the latter with the bad connection / breakdown of the three-phase installation neutral.

Technical specifications of the HAGER MZ240N

  • According to the standards: UNE EN 50550, UNE EN 61643-11, UNE EN 60898-1
  • Number of half modules of 17,5mm only for instrument and kit: 10
  • Number of poles: 2 P
  • Number of modules: 5
  • Rated rated current: 40 A
  • Rated current at 20º C: 43.2 A
  • Rated current at 30 ° C: 40 A
  • Rated current at 35 ° C: 38.4 A
  • Rated current at 40 ° C: 36.8 A
  • Rated insulation voltage: 500 V
  • Rated current at 45 ° C: 35.2 A
  • Rated current at 50 ° C: 33.6 A
  • Rated current at 55 ° C: 32 A
  • Rated current at 60 ° C: 30.4 A
  • Rated current at 70 ° C: 27.2 A
  • Curve: C
  • Power cut-off according to NF EN60898: 6 kA
  • Ten. Asig. Of resistance to shocks: 4000 V
  • Rated Frequency: 50/60 Hz
  • Connection Type: Cage with screw
  • Connection section in flexible cable: 6 mm²
  • Tightening torque: 1, 2 Nm
  • Connection in rigid cable: 10 mm²
  • Connection Sec. Born Sup And inf. Rigid cable: 1/25 mm²
  • Connection Sec. Sup. Flexible cable: 1/16 mm²
  • Height: 2000 m
  • Installed product height: 86.5 mm
  • Width of installed product: 87.5 mm
  • Depth of installed appliance: 70 mm
  • Coef. Correcc. Corr. Nom. 2 apar.yuxtap .: 1
  • Coef. Correcc. Corr. Nom. 3 apar.yuxtap .: 0.95
  • Coef. Correcc. Corr. Nom. 4 and 5 ap.yux ..: 0.9
  • Coef. Correcc. Corr. Nom. 6 pair.:x .: 0.85
  • Coef. Of correction. Magnetic trip 200Hz: 1.2
  • Coef. Of correction. 400Hz magnetic trip: 1.5
  • Coef. Of correction. Magnetic trip 60Hz: 1
  • Coef.correc. 100Hz magnetic trip: 1,1
  • Degree of pollution / IEC60664 / IEC60947-2: 3
  • Electrical endurance in number of cycles: 10000
  • Mechanical endurance in number of maneuvers: 10000
  • Threshold value min / max relay magn. In c.a .: 5/10 In
  • Threshold value min / max thermal relay in c.c: 1,13 / 1,45 In
  • Min. Threshold value Thermal relay in a .: 1,13 / 1,45 In
  • Threshold value min / max function. Thermal dc: 5/15 In
  • Power cut 1 Pol. IT400V (NF EN60947-2): 3 kA
  • Power cut last AC. 230V (NF 60947-2): 1 kA
  • Rated cutting power: 6 kA
  • Rated cutting power: 6 kA
  • Total power dissipated in IN: 9.7 W
  • Storage temperature: -25 to 80 ° C
  • Operating temperature: -25 to 60 ° C

 

Reference. HAGER MZ240N

 

The discount applied to the PVP is -67%

Additional product information

DATA SHEET: Download
SECURE PAYMENT: PayPal, Card, Transfer or Cash on Delivery.
FREE SHIPPING: For orders over €99, the rest is only €4.90 (mainland Spain).
EXPRESS DELIVERY: With MRW in 24/48 working hours depending on the delivery point (penin. Spain).

We also recommend

*

Prices include VAT


Customers who bought this product also bought

*

Prices include VAT


Browse these categories as well: OVERVOLTAGE LIMITERS / PROTECTORS, TOP SALES ELECTRICAL EQUIPMENT, HAGER SURGE PROTECTION

HAGER MZ425N - Overvoltage Transient Permanante + 4P 25A

Product no.: 112515

In stock, available in 24 horas

PVP. 764.65 €
233.50
You save 531.15 €

Price includes VAT

Price reductions

Combined protection set against Transient and Permanent overvoltages associated with 4P general circuit breaker, cutting power 6000A according to UNE EN 60898-1 and 10kA according to UNE EN 60947-2, Curve C, rated current 25A.

With the MZ425N of HAGER the installation is protected against transient voltage peaks and against permanent voltage increases. Typically, the former are associated with the phenomenon of lightning and the latter with poorly connected / broken neutral of the three-phase installation.

Technical characteristics of the HAGER MZ425N

  • In accordance with the standards: UNE EN 50550, UNE EN 61643-11
  • Number of poles: 4 P
  • Nominal intensity 25A
  • Maximum discharge capacity 15kA, protection level Up <= 1.5 kV
  • Trigger voltage for permanent surges:> 280V a.c.
  • C curve
  • Rated frequency 50/60 Hz
  • Rated cutting power 6 kA
  • Rated operating voltage in alternating 230/400 V
  • Rated insulation voltage 500 V
  • Voltage supported to the assigned pulse 6000 V
  • Power last cut in c.a. 400V (EN 60947-2) 1 kA
  • Rated cutting power 6 kA
  • Service cutting power according to EN60898 6 kA
  • Power cut 1 pole 400V (EN60947-2) 3 kA
  • Power last cut in c.a. 230V (EN 60947-2) 1 kA
  • Threshold value min / max magnetic relay in a.c. 5/10 In
  • Threshold value min / max thermal relay operation in DC 5/15 In
  • Min / max value of thermal relay operation in a.c. 1.13 / 1.45 In
  • Value of the min / max operating level of the thermal relay in DC 1.13 / 1.45 In
  • Current assigned at 20º C 27 A
  • Rated current at 30 ° C 25 A
  • Rated current at 35 ° C 24 A
  • Rated current at 40 ° C 23 A
  • Rated current at 45 ° C 22 A
  • Rated current at 50 ° C 21 A
  • Rated current at 55 ° C 20 A
  • Rated current at 60 ° C 19 A
  • Coefficient of 100Hz magnetic trip correction 1.1
  • Correction coefficient of magnetic trip at 200Hz 1.2
  • Correction coefficient magnetic trip at 400Hz 1.5
  • Correction coefficient of magnetic trip at 60Hz 1
  • Correction coefficient of the nominal current for 2 juxtaposed devices: 1
  • Correction coefficient of the nominal current for 3 juxtaposed devices: 0.95
  • Current correction coefficient for 4 and 5 juxtaposed devices: 0.9
  • Correction coefficient of the nominal current for 6 juxtaposed devices: 0.85
  • Total power dissipated under conditions of nominal intensity 14.9 W
  • Electrical endurance in number of cycles 10000
  • Mechanical endurance in number of maneuvers 10000
  • Dimensions: Depth of installed product 70 mm - Height of installed product 86.5 mm - Width of installed product 192.5 mm
  • Tightening torque 1, 2 Nm
  • 10 mm² rigid cable connection section
  • Flexible cable connection section 6 mm²
  • Connection type Screw cage terminal
  • Upright terminal connection section with 1/16 mm² screw
  • Sec. Sec. born His p. and inf. rigid cable 1/25 mm²
  • Pollution degree / IEC60664 / IEC60947-2 3
  • Altitude 2000 m
  • Storage temperature -25 to 80 ° C
  • Tropicalization / humidity / protection All climates

 

Reference. HAGER MZ425N

 

The discount applied to the PVP is -69%

Additional product information

DATA SHEET: Download
SECURE PAYMENT: PayPal, Card, Transfer or Cash on Delivery.
FREE SHIPPING: For orders over €99, the rest is only €4.90 (mainland Spain).
EXPRESS DELIVERY: With MRW in 24/48 working hours depending on the delivery point (penin. Spain).

We also recommend

*

Prices include VAT


Customers who bought this product also bought

*

Prices include VAT


Browse these categories as well: OVERVOLTAGE LIMITERS / PROTECTORS, HAGER SURGE PROTECTION

HAGER MZ432N - Overvoltage Transient Permanante + 4P 32A

Product no.: 112513

In stock, available in 24 horas

PVP. 770.01 €
277.00
You save 493.01 €

Price includes VAT

Price reductions

Combined protection set against Transient and Permanent overvoltages associated with 4P general circuit breaker, cutting power 6000A according to UNE EN 60898-1 and 10kA according to UNE EN 60947-2, Curve C, rated current 32A.

With the MZ432N of HAGER the installation is protected against transient voltage peaks and against permanent voltage increases. Typically, the former are associated with the phenomenon of lightning and the latter with poorly connected / broken neutral of the three-phase installation.

Technical characteristics of the HAGER MZ432N

  • In accordance with the standards: UNE EN 50550, UNE EN 61643-11
  • Number of poles: 4 P
  • Nominal intensity 32A
  • Maximum discharge capacity 15kA, protection level Up <= 1.5 kV
  • Trigger voltage for permanent surges:> 280V a.c.
  • C curve
  • Rated frequency 50/60 Hz
  • Rated cutting power 6 kA
  • Rated operating voltage in alternating 230/400 V
  • Rated insulation voltage 500 V
  • Voltage supported to the assigned pulse 6000 V
  • Power last cut in c.a. 400V (EN 60947-2) 1 kA
  • Rated cutting power 6 kA
  • Service cutting power according to EN60898 6 kA
  • Power cut 1 pole 400V (EN60947-2) 3 kA
  • Power last cut in c.a. 230V (EN 60947-2) 1 kA
  • Threshold value min / max magnetic relay in a.c. 5/10 In
  • Threshold value min / max thermal relay operation in DC 5/15 In
  • Min / max value of thermal relay operation in a.c. 1.13 / 1.45 In
  • Value of the min / max operating level of the thermal relay in DC 1.13 / 1.45 In
  • Current assigned at 20º C 27 A
  • Rated current at 30 ° C 25 A
  • Rated current at 35 ° C 24 A
  • Rated current at 40 ° C 23 A
  • Rated current at 45 ° C 22 A
  • Rated current at 50 ° C 21 A
  • Rated current at 55 ° C 20 A
  • Rated current at 60 ° C 19 A
  • Coefficient of 100Hz magnetic trip correction 1.1
  • Correction coefficient of magnetic trip at 200Hz 1.2
  • Correction coefficient magnetic trip at 400Hz 1.5
  • Correction coefficient of magnetic trip at 60Hz 1
  • Correction coefficient of the nominal current for 2 juxtaposed devices: 1
  • Correction coefficient of the nominal current for 3 juxtaposed devices: 0.95
  • Current correction coefficient for 4 and 5 juxtaposed devices: 0.9
  • Correction coefficient of the nominal current for 6 juxtaposed devices: 0.85
  • Total power dissipated under conditions of nominal intensity 14.9 W
  • Electrical endurance in number of cycles 10000
  • Mechanical endurance in number of maneuvers 10000
  • Dimensions: Depth of installed product 70 mm - Height of installed product 86.5 mm - Width of installed product 192.5 mm
  • Tightening torque 1, 2 Nm
  • 10 mm² rigid cable connection section
  • Flexible cable connection section 6 mm²
  • Connection type Screw cage terminal
  • Upright terminal connection section with 1/16 mm² screw
  • Sec. Sec. born His p. and inf. rigid cable 1/25 mm²
  • Pollution degree / IEC60664 / IEC60947-2 3
  • Altitude 2000 m
  • Storage temperature -25 to 80 ° C
  • Tropicalization / humidity / protection All climates

 

Reference. HAGER MZ432N

 

The discount applied to the PVP is -64%

Additional product information

DATA SHEET: Download
SECURE PAYMENT: PayPal, Card, Transfer or Cash on Delivery.
FREE SHIPPING: For orders over €99, the rest is only €4.90 (mainland Spain).
EXPRESS DELIVERY: With MRW in 24/48 working hours depending on the delivery point (penin. Spain).

We also recommend

*

Prices include VAT


Customers who bought this product also bought

*

Prices include VAT


Browse these categories as well: OVERVOLTAGE LIMITERS / PROTECTORS, HAGER SURGE PROTECTION

HAGER MZ440N - Overvoltage Transient Permanante + 4P 40A

Product no.: 112514

In stock, available in 24 horas

PVP. 938.69 €
337.95
You save 600.74 €

Price includes VAT

Price reductions

Combined protection set against Transient and Permanent overvoltages associated with 4P general circuit breaker, cutting power 6000A according to UNE EN 60898-1 and 10kA according to UNE EN 60947-2, Curve C, rated current 40A.

With the MZ440N of HAGER the installation is protected against transient voltage peaks and against permanent voltage increases. Typically, the former are associated with the phenomenon of lightning and the latter with poorly connected / broken neutral of the three-phase installation.

Technical characteristics of the HAGER MZ440N

  • In accordance with the standards: UNE EN 50550, UNE EN 61643-11
  • Number of poles: 4 P
  • Nominal intensity 40A
  • Maximum discharge capacity 15kA, protection level Up <= 1.5 kV
  • Trigger voltage for permanent surges:> 280V a.c.
  • C curve
  • Rated frequency 50/60 Hz
  • Rated cutting power 6 kA
  • Rated operating voltage in alternating 230/400 V
  • Rated insulation voltage 500 V
  • Voltage supported to the assigned pulse 6000 V
  • Power last cut in c.a. 400V (EN 60947-2) 1 kA
  • Rated cutting power 6 kA
  • Service cutting power according to EN60898 6 kA
  • Power cut 1 pole 400V (EN60947-2) 3 kA
  • Power last cut in c.a. 230V (EN 60947-2) 1 kA
  • Threshold value min / max magnetic relay in a.c. 5/10 In
  • Threshold value min / max thermal relay operation in DC 5/15 In
  • Min / max value of thermal relay operation in a.c. 1.13 / 1.45 In
  • Value of the min / max operating level of the thermal relay in DC 1.13 / 1.45 In
  • Current assigned at 20º C 27 A
  • Rated current at 30 ° C 25 A
  • Rated current at 35 ° C 24 A
  • Rated current at 40 ° C 23 A
  • Rated current at 45 ° C 22 A
  • Rated current at 50 ° C 21 A
  • Rated current at 55 ° C 20 A
  • Rated current at 60 ° C 19 A
  • Coefficient of 100Hz magnetic trip correction 1.1
  • Correction coefficient of magnetic trip at 200Hz 1.2
  • Correction coefficient magnetic trip at 400Hz 1.5
  • Correction coefficient of magnetic trip at 60Hz 1
  • Correction coefficient of the nominal current for 2 juxtaposed devices: 1
  • Correction coefficient of the nominal current for 3 juxtaposed devices: 0.95
  • Current correction coefficient for 4 and 5 juxtaposed devices: 0.9
  • Correction coefficient of the nominal current for 6 juxtaposed devices: 0.85
  • Total power dissipated under conditions of nominal intensity 14.9 W
  • Electrical endurance in number of cycles 10000
  • Mechanical endurance in number of maneuvers 10000
  • Dimensions: Depth of installed product 70 mm - Height of installed product 86.5 mm - Width of installed product 192.5 mm
  • Tightening torque 1, 2 Nm
  • 10 mm² rigid cable connection section
  • Flexible cable connection section 6 mm²
  • Connection type Screw cage terminal
  • Upright terminal connection section with 1/16 mm² screw
  • Sec. Sec. born His p. and inf. rigid cable 1/25 mm²
  • Pollution degree / IEC60664 / IEC60947-2 3
  • Altitude 2000 m
  • Storage temperature -25 to 80 ° C
  • Tropicalization / humidity / protection All climates

 

Reference. HAGER MZ440N

 

The discount applied to the PVP is -64%

Additional product information

DATA SHEET: Download
SECURE PAYMENT: PayPal, Card, Transfer or Cash on Delivery.
FREE SHIPPING: For orders over €99, the rest is only €4.90 (mainland Spain).
EXPRESS DELIVERY: With MRW in 24/48 working hours depending on the delivery point (penin. Spain).

We also recommend

*

Prices include VAT


Customers who bought this product also bought

D0 Fuse 100A 3
6.70 *
*

Prices include VAT


Browse these categories as well: OVERVOLTAGE LIMITERS / PROTECTORS, HAGER SURGE PROTECTION

HAGER MZ463N - Overvoltage Transient Permanante + 4P 63A

Product no.: 112516

In stock, available in 24 horas

PVP. 1,111.03 €
359.90
You save 751.13 €

Price includes VAT

Price reductions

Combined protection set against Transient and Permanent overvoltages associated with 4P general circuit breaker, cutting power 6000A according to UNE EN 60898-1 and 10kA according to UNE EN 60947-2, Curve C, rated current 63A.

With the MZ463N of HAGER the installation is protected against transient voltage peaks and against permanent voltage increases. Typically, the former are associated with the phenomenon of lightning and the latter with poorly connected / broken neutral of the three-phase installation.

Technical characteristics of the HAGER MZ463N

  • In accordance with the standards: UNE EN 50550, UNE EN 61643-11
  • Number of poles: 4 P
  • Nominal intensity 63A
  • Maximum discharge capacity 15kA, protection level Up <= 1.5 kV
  • Trigger voltage for permanent surges:> 280V a.c.
  • C curve
  • Rated frequency 50/60 Hz
  • Rated cutting power 6 kA
  • Rated operating voltage in alternating 230/400 V
  • Rated insulation voltage 500 V
  • Voltage supported to the assigned pulse 6000 V
  • Power last cut in c.a. 400V (EN 60947-2) 1 kA
  • Rated cutting power 6 kA
  • Service cutting power according to EN60898 6 kA
  • Power cut 1 pole 400V (EN60947-2) 3 kA
  • Power last cut in c.a. 230V (EN 60947-2) 1 kA
  • Threshold value min / max magnetic relay in a.c. 5/10 In
  • Threshold value min / max thermal relay operation in DC 5/15 In
  • Min / max value of thermal relay operation in a.c. 1.13 / 1.45 In
  • Value of the min / max operating level of the thermal relay in DC 1.13 / 1.45 In
  • Current assigned at 20º C 27 A
  • Rated current at 30 ° C 25 A
  • Rated current at 35 ° C 24 A
  • Rated current at 40 ° C 23 A
  • Rated current at 45 ° C 22 A
  • Rated current at 50 ° C 21 A
  • Rated current at 55 ° C 20 A
  • Rated current at 60 ° C 19 A
  • Coefficient of 100Hz magnetic trip correction 1.1
  • Correction coefficient of magnetic trip at 200Hz 1.2
  • Correction coefficient magnetic trip at 400Hz 1.5
  • Correction coefficient of magnetic trip at 60Hz 1
  • Correction coefficient of the nominal current for 2 juxtaposed devices: 1
  • Correction coefficient of the nominal current for 3 juxtaposed devices: 0.95
  • Current correction coefficient for 4 and 5 juxtaposed devices: 0.9
  • Correction coefficient of the nominal current for 6 juxtaposed devices: 0.85
  • Total power dissipated under conditions of nominal intensity 14.9 W
  • Electrical endurance in number of cycles 10000
  • Mechanical endurance in number of maneuvers 10000
  • Dimensions: Depth of installed product 70 mm - Height of installed product 86.5 mm - Width of installed product 192.5 mm
  • Tightening torque 1, 2 Nm
  • 10 mm² rigid cable connection section
  • Flexible cable connection section 6 mm²
  • Connection type Screw cage terminal
  • Upright terminal connection section with 1/16 mm² screw
  • Sec. Sec. born His p. and inf. rigid cable 1/25 mm²
  • Pollution degree / IEC60664 / IEC60947-2 3
  • Altitude 2000 m
  • Storage temperature -25 to 80 ° C
  • Tropicalization / humidity / protection All climates

 

Reference. HAGER MZ463N

 

The discount applied to the PVP is -67%

Additional product information

DATA SHEET: Download
SECURE PAYMENT: PayPal, Card, Transfer or Cash on Delivery.
FREE SHIPPING: For orders over €99, the rest is only €4.90 (mainland Spain).
EXPRESS DELIVERY: With MRW in 24/48 working hours depending on the delivery point (penin. Spain).

We also recommend

*

Prices include VAT


Customers who bought this product also bought

*

Prices include VAT


Browse these categories as well: OVERVOLTAGE LIMITERS / PROTECTORS, HAGER SURGE PROTECTION

SCHNEIDER A9L16617 - Transient overvoltage protector 1P+N 10 kA type 2 Acti9 Quick

Product no.: 112565

In stock, available in 24 horas

PVP. 153.42 €
69.50
You save 83.92 €

Price includes VAT

Price reductions

1 Pole + Neutral, 10 kA, Type 2 Transient Overvoltage Protector Limiter. Manufactured by SCHNEIDER, reference A9L16617 Acti9 Quick PF range.

Technical characteristics of the SCHNEIDER A9L16617 Acti9 Quick PF

  • Type of product: Transient overvoltage protector limiter - Overvoltage dissipator.
  • Device short name: IQuick PF
  • Device application: for current>0.1A
  • Standards: EN 61643-11:2012 and IEC 61643-11:2011
  • Product Certifications: CE
  • Quality labels: NF
  • Number of poles: 1P + N
  • Type of surge suppressor: Electrical distribution network
  • Grounding system: TN-S / TT
  • Type and class of surge suppressor: Type 2
  • Surge Limiter Technology: MOV + GDT
  • Rated operational voltage [Ue]: 230 V AC - type of cable: +/- 10%) at 50/60 Hz
  • Nominal discharge current [In]: Differential mode, state 1 5 kA - cable type: L/N), Common mode, state 1 10 kA - cable type: N/PE)
  • Maximum discharge current [Imax]: Common mode, state 1 10 kA N/PE, Differential mode, state 1 10 kA L/N
  • Maximum continuous operating voltage [Uc]: Common mode, state 1 275 V N/PE, Differential mode, state 1 275 V L/N
  • Voltage protection level [Up]: Common mode <1.5 kV type 2 N/PE, Differential mode <1.5 kV type 2 L/N
  • Temporary overvoltage [Ut]: 337 V L/N 5 s maintained, 1200 V N/PE 200 ms safe failure mode, 442 V L/PE 5 s maintained
  • Current monitoring [If]: 0.1 kA common mode N/PE
  • Short-circuit current rating [Isccr]: 6 kA
  • Type of disconnecting device: Integrated circuit breaker - Icu 6 kA
  • Mounting mode: Adjustable on clip - cable type: DIN rail)
  • 9mm pitches: 4
  • Dimensions: Height 109.7mm - Width 36mm - Depth 72.1mm

 

Reference. SCHNEIDER A9L16617

 

The discount applied to the PVP is -54%

Additional product information

SECURE PAYMENT: PayPal, Card, Transfer or Cash on Delivery.
FREE SHIPPING: For orders over €99, the rest is only €4.90 (mainland Spain).
EXPRESS DELIVERY: With MRW in 24/48 working hours depending on the delivery point (penin. Spain).

We also recommend

*

Prices include VAT


Browse these categories as well: OVERVOLTAGE LIMITERS / PROTECTORS, SCHNEIDER SURGE PROTECTION
1 - 10 of 34 results